Human Coagulation Factor III/Tissue Factor Quantikine ELISA
Human Coagulation Factor III/Tissue Factor Quantikine ELISA
 
	Human Coagulation Factor III/Tissue Factor Quantikine ELISA Summary
	
	
	货号:DCF300
	深圳子科生物优势代理美国R&DELISA系列产品试剂盒,价格优势,货期短,欢迎来电咨询0755-33164177!
	
		
			
				Assay Type
			
			
				Solid Phase Sandwich ELISA
			
		 
		
			
				Format
			
			
				96-well strip plate
			
		 
		
		
			
				Sample Type & Volume Required Per Well
			
			
				Cell Culture Supernates (50 uL), Cell Lysates (50 uL), EDTA Plasma (50 uL), Heparin Plasma (50 uL), Citrate Plasma (50 uL), Urine (50 uL)
			
		 
		
		
			
				Assay Range
			
			
				7.8 - 500 pg/mL (Cell Culture Supernates, Cell Lysates, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine)
			
		 
		
			
				Specificity
			
			
				Natural and recombinant human Coagulation Factor III
			
		 
		
			
				Cross-reactivity
			
			
				< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
			
		 
		
			
				Interference
			
			
				No significant interference observed with available related molecules.
			
		 
	 
 
	
	
		Product Summary
	
	
		The Quantikine Human Coagulation Factor III/Tissue Factor Immunoassay is a 4.5 hour solid-phase ELISA designed to measure human Coagulation Factor III in cell culture supernates, cell lysates, plasma, and urine. It contains NS0-expressed recombinant human Coagulation Factor III and has been shown to accurately quantitate the recombinant factor. Results obtained using natural human Coagulation Factor III showed linear curves that were p arallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for naturally occurring Coagulation Factor III.
	
 
	
		Precision
	
	
		Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
	
	
		Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision
	
	
		Cell Culture Supernates, Cell Lysates, EDTA Plasma, Heparin Plasma, Citrate Plasma, Urine
	
	
		
			
				| 
				 | 
				
					Intra-Assay Precision
				 | 
				
					Inter-Assay Precision
				 | 
			
		
		
			
				| 
					Sample
				 | 
				
					1
				 | 
				
					2
				 | 
				
					3
				 | 
				
					1
				 | 
				
					2
				 | 
				
					3
				 | 
			
			
				| 
					n
				 | 
				
					20
				 | 
				
					20
				 | 
				
					20
				 | 
				
					40
				 | 
				
					40
				 | 
				
					40
				 | 
			
			
				| 
					Mean
				 | 
				
					33.4
				 | 
				
					65.4
				 | 
				
					148
				 | 
				
					71
				 | 
				
					144
				 | 
				
					301
				 | 
			
			
				| 
					Standard Deviation
				 | 
				
					0.78
				 | 
				
					1.81
				 | 
				
					5
				 | 
				
					4.5
				 | 
				
					7.8
				 | 
				
					17.1
				 | 
			
			
				| 
					CV%
				 | 
				
					2.3
				 | 
				
					2.8
				 | 
				
					3.4
				 | 
				
					6.3
				 | 
				
					5.4
				 | 
				
					5.7
				 | 
			
		
	
 
	
		Recovery
	
	
		
			The recovery of Coagulation Factor III spiked to levels throughout the range of the assay in various matrices was evaluated.
		
	 
	
		
			
				| 
					Sample Type
				 | 
				
					Average % Recovery
				 | 
				
					Range %
				 | 
			
		
		
			
				| 
					Cell Culture Media (n=4)
				 | 
				
					104
				 | 
				
					95-110
				 | 
			
			
				| 
					Citrate Plasma (n=4)
				 | 
				
					92
				 | 
				
					86-102
				 | 
			
			
				| 
					EDTA Plasma (n=4)
				 | 
				
					91
				 | 
				
					86-97
				 | 
			
			
				| 
					Heparin Plasma (n=4)
				 | 
				
					95
				 | 
				
					88-109
				 | 
			
			
				| 
					Urine (n=4)
				 | 
				
					102
				 | 
				
					96-112
				 | 
			
		
	
 
	
		Linearity
	
	
		To assess the linearity of the assay, samples containing and/or spiked with high concentrations of Coagulation Factor III were serially diluted with the Calibrator Diluent to produce samples with values within the dynamic range of the assay.